Step 1: Overview and preparation. <ul class="guide-bullets"><li>Inspect the unit for damage.</li><li>Confirm all connections are clean and undamaged.</li><li>Ensure a fresh Longopac bag cassette is ready.</li><li>The C 3000 requires no power and works passively with any compatible dust extractor.</li></ul> Visual illustration provided.
1

Overview and preparation

  • Inspect the unit for damage.
  • Confirm all connections are clean and undamaged.
  • Ensure a fresh Longopac bag cassette is ready.
  • The C 3000 requires no power and works passively with any compatible dust extractor.
Step 2: Longopac bag installation. <ul class="guide-bullets"><li>Attach the Longopac bag holder to the container by twisting it securely.</li><li>Insert a new Longopac cassette into the holder.</li><li>Pull the bag through and close the end with a cable tie for an airtight seal. Replace before heavy laser cleaning jobs.</li></ul> Visual illustration provided.
2

Longopac bag installation

  • Attach the Longopac bag holder to the container by twisting it securely.
  • Insert a new Longopac cassette into the holder.
  • Pull the bag through and close the end with a cable tie for an airtight seal. Replace before heavy laser cleaning jobs.
Step 3: Hose connection. <ul class="guide-bullets"><li>Connect the Ø63 mm suction hose from the laser cleaning tool or work area to the inlet.</li><li>Connect another Ø63 mm hose from the outlet to the main dust extractor inlet (such as the DE 120).</li><li>Ensure all couplings are tight to prevent leaks.</li></ul> Visual illustration provided.
3

Hose connection

  • Connect the Ø63 mm suction hose from the laser cleaning tool or work area to the inlet.
  • Connect another Ø63 mm hose from the outlet to the main dust extractor inlet (such as the DE 120).
  • Ensure all couplings are tight to prevent leaks.
Step 4: Startup and operation. <ul class="guide-bullets"><li>Start the downstream dust extractor (for example, DE 120).</li><li>The C 3000 activates passively via airflow.</li><li> Monitor dust accumulation in the Longopac bag during laser cleaning.</li><li>Maintain steady suction; the cyclonic action separates up to 90% of material before it reaches the main filter.</li></ul> Visual illustration provided.
4

Startup and operation

  • Start the downstream dust extractor (for example, DE 120).
  • The C 3000 activates passively via airflow.
  • Monitor dust accumulation in the Longopac bag during laser cleaning.
  • Maintain steady suction; the cyclonic action separates up to 90% of material before it reaches the main filter.
Step 5: Monitoring during use. <ul class="guide-bullets"><li>Watch the transparent sections or bag level for dust buildup.</li><li>Stop and empty when the bag approaches capacity to avoid reduced separation efficiency.</li><li>Check hose connections periodically for leaks or blockages.</li></ul> Visual illustration provided.
5

Monitoring during use

  • Watch the transparent sections or bag level for dust buildup.
  • Stop and empty when the bag approaches capacity to avoid reduced separation efficiency.
  • Check hose connections periodically for leaks or blockages.
Step 6: Emptying the Longopac bag. <ul class="guide-bullets"><li>Stop the dust extractor.</li><li>Pull the full bag downward.</li><li>Add a second cable tie approximately 10 cm below the first.</li><li>Cut between the ties.</li><li>Dispose of the sealed bag per local hazardous dust regulations. Install a new bag before resuming work.</li></ul> Visual illustration provided.
6

Emptying the Longopac bag

  • Stop the dust extractor.
  • Pull the full bag downward.
  • Add a second cable tie approximately 10 cm below the first.
  • Cut between the ties.
  • Dispose of the sealed bag per local hazardous dust regulations. Install a new bag before resuming work.
Step 7: Pairing with laser cleaning systems. <ul class="guide-bullets"><li>Place the C 3000 inline between the laser tool (for example, Kamino 300) and the main extractor (for example, DE 120).</li><li> Use Ø63 mm antistatic hoses.</li><li>This setup captures heavy debris first, protecting the downstream HEPA filters and maintaining higher airflow.</li></ul> Visual illustration provided.
7

Pairing with laser cleaning systems

  • Place the C 3000 inline between the laser tool (for example, Kamino 300) and the main extractor (for example, DE 120).
  • Use Ø63 mm antistatic hoses.
  • This setup captures heavy debris first, protecting the downstream HEPA filters and maintaining higher airflow.
Step 8: Shutdown and storage. <ul class="guide-bullets"><li>Stop the main dust extractor.</li><li>Empty the Longopac bag if near capacity.</li><li>Disconnect hoses and wipe exterior surfaces.</li><li>Store the unit indoors in a clean, dry location with hoses detached.</li></ul> Visual illustration provided.
8

Shutdown and storage

  • Stop the main dust extractor.
  • Empty the Longopac bag if near capacity.
  • Disconnect hoses and wipe exterior surfaces.
  • Store the unit indoors in a clean, dry location with hoses detached.
Step 9: Common troubleshooting. <ul class="guide-bullets"><li>Reduced airflow: check for hose blockages or an overfull Longopac bag and empty or replace as needed.</li><li>Dust escaping: verify all couplings are tight and Longopac seals are intact.</li><li> Poor separation: ensure inlet velocity is sufficient via the main extractor.</li></ul> Visual illustration provided.
9

Common troubleshooting

  • Reduced airflow: check for hose blockages or an overfull Longopac bag and empty or replace as needed.
  • Dust escaping: verify all couplings are tight and Longopac seals are intact.
  • Poor separation: ensure inlet velocity is sufficient via the main extractor.
Step 10: Safety and exit behavior. <ul class="guide-bullets"><li>Never puncture Longopac bags—risk of dust dispersion.</li><li> Use only for dry, non-combustible dust.</li><li>Always wear appropriate PPE.</li><li>Dispose of collected material according to local hazardous waste regulations. Store the unit clean and ready for next deployment.</li></ul> Visual illustration provided.
10

Safety and exit behavior

  • Never puncture Longopac bags—risk of dust dispersion.
  • Use only for dry, non-combustible dust.
  • Always wear appropriate PPE.
  • Dispose of collected material according to local hazardous waste regulations. Store the unit clean and ready for next deployment.