Skip to main content
Operator using the Netalux Dagger 4000 laser cleaning system
Readbeforeyouemit.

Netalux Dagger 4000 operator manual

Operator manual for the Netalux Dagger 4000 water-cooled Class 4 laser cleaner: safety, PPE, startup, shutdown, maintenance, and alarms. For rental specs and booking see the Dagger 4000 product page.

Before you start

Complete training before use. Keep this documentation available to every operator. Netalux Academy details are at netalux.com/academy.

Rules that apply every shift

  • Wear correct laser safety glasses and hearing protection whenever the laser can emit.
  • Read and understand the operating instructions before powering on.
  • Know the Class 4 hazards for eyes and skin.
  • Netalux assumes no liability for unintended use or skipped safety instructions.

General safety

Netalux is not liable for damage to products or installations caused with the machine, or for injury to persons caused with the product.

Core warnings

  • Use only the controls and procedures in the manual. Other adjustments can cause hazardous radiation exposure.
  • Inspect for damage, unusual noise, or cracked cord or fiber before each use. Do not run a damaged machine.
  • Do not use in ATEX zones or under water. Clear highly flammable materials from the work area.
  • Wear EN207 laser safety glasses matched to machine power and wavelength.
  • Always aim at a surface. Do not fire into open air. Never irradiate people.
  • Do not leave the machine unattended. Power off fully and remove the key when leaving.
  • Complete a risk analysis before service, including door interlocks and safety curtains. Interlocks must be closed to reset and emit.
  • Maintain proper grounding and stable voltage.
  • Do not crush the fiber protective arm. Report damage to Netalux Support.

Personal protection and work zone

Eyelids do not protect against laser light. Collective measures and PPE stay on until the machine is fully off.

PPE and clothing

  • Never remove laser safety glasses during laser work. Bystanders need the correct glasses too.
  • Never look directly into the beam, even with glasses on.
  • Wear safety shoes and clothing that protects skin; avoid reflective jewelry and watches.
  • Gloves can heat and burn; check all PPE for damage before emission.

Demarcation

Under European Directive 2006/25/EC, demarcate the laser cleaning zone so only authorized people enter. Use a laser safety screen, marking tape, and warning signs.

Laser safety

Class 4 laser products require a risk analysis and preventive measures before use (EU Directive 2006/25/EC). Incorrect use can cause permanent blindness, skin burns, short circuits, or uncontrolled emission.

Immediate stop conditions

  • If the fiber protective arm is cracked or internal cables are visible, stop, power off, and contact Netalux Support.
  • Use the machine only for intended industrial surface cleaning.
  • Glasses must suit 1064 nm and the machine power; welding goggles do not qualify. Confirm EN207 rating with your supplier.

Class 4 label summary

Visible and invisible laser radiation. Avoid eye or skin exposure to direct or scattered radiation. Example label values: 900-1200 nm at 4000 W CW; aiming diode 650 nm <1 mW CW; IEC 60825-1 / BS EN 60825-1.

Extraction, room preparation, and operators

Released particles can harm health and damage optics. Extract promptly and dispose of collected material under local law.

People and contaminants

  • Tell nearby workers you are lasering. Keep the safety zone clear unless authorized.
  • Anyone entering the zone must wear PPE from the task risk analysis.
  • Identify the contaminant before starting and provide respiratory or chemical PPE as required.

Room checklist

  • No mirrors or highly reflective surfaces
  • Protect paintings and glass; treat viewing windows for 1064 nm
  • Use non-combustible or fire-retardant curtains (preferably EN 60825-1)
  • Keep the beam off paper, plastic, and other flammables

Operator requirements

Every operator must be trained on machine use and safety (Directive 2006/25/EC). Never allow untrained people to run the machine. Operators must be fit for the work.

Emergencies

Emergency stops sit above the display and on the back of the machine. Push one immediately in emergency or danger. Emission and laser-source power stop; unit and handset lights turn red; the display shows the e-stop state.

Restart after e-stop

Confirm the area is safe, turn the e-stop a quarter turn to normal, then reset when the reset path is available again (reset green; lights return to green).

Rules

  • Do not use the emergency stop as a normal power-off. Repeated use can damage electronics.
  • The external interlock plug can act as an e-stop for site systems (line e-stop, light curtain, door switch). Close it again before reset.
  • The handset reset button is not an emergency stop. It returns the laser to safe mode for a normal pause. Use the e-stop for a full shutdown.

Product overview

The laser unit houses the source, electronics, and ventilation. The handset is where the beam exits. The fiber connects the two. DCL carries two programmable pulses in one fiber for ablation cleaning.

Protect the fiber

Do not crush or damage the fiber. Fiber damage forces a full safety stop and certified repair.

Intended use

Professional surface treatment only: rust, paint, grease, process contamination and coatings, mould cleaning, and weld cleaning. Mobile multi-site use, not private household use and not a fixed unsupervised install. Trained operators only.

Laser unit

Main chassis features used every shift.

Components

  • HMI: power, reset, jobs, e-stop
  • Four hoisting points and forklift pickup areas
  • Handles with front brake releases
  • Rear emergency stop
  • Built-in water coolers for source and handset
  • Ventilators and filters (keep air inlets clear)
  • Indicator lights synced with the handset

Indicator colors

Indicator colors
Whitestarting up
Greenready to reset
Orange continuousready for emission
Orange flashinglasering
Redalarm (for example e-stop)

Connectors and service access

Service door and switchboard are for Netalux technicians only. Invisible Class 4 radiation can be present when panels are open.

Connector panel

  • I/O, external LED, interlock, MODBUS
  • Service port (technicians only) and software updates
  • Power indicator LED (red when powered)
  • Air outlet and air inlet (ISO 6150-B, 5-8 bar, 120 L/min)
  • Mains switch and 3P+N+PE power inlet
  • Storage compartment for fiber and handset after use

User interface

Touch display on the laser unit for jobs and status.

Controls

Controls
Emergency stopemergency use only
Key switchquarter turn right to start; left and remove to shut down
Displayjobs plus power, geometry, and pulse overlap; temperature and status
Sliderfine parameter changes
Arm/disarm buttongreen armed, red while ready/emitting depending on state
—Alarm symbols on the right of the display

Handset

The handset aims the beam and carries local controls. Never look into the laser head unless the machine is powered off.

Parts

  • Rotatable laser head (about 115°)
  • Secondary ergonomic handle (360°)
  • Lens change buttons, control screen, reset, program selection
  • Fiber, control button with unlock slide, accessory mounts (M4)
  • Indicator light, protective glass, headlight, air knife

Control button

Slide the unlock forward, then press and hold the control button to emit. Release to stop. Change jobs only after releasing the control button.

Incorrect use

Incorrect use risks operator and bystander health and can seriously damage the machine. Netalux is not liable for incorrect use.

Do not

  • Treat textiles, carpets, curtains, or other flammable absorbing surfaces
  • Irradiate any part of the human body or use for medical or cosmetic procedures
  • Use for household cleaning, under water, or in ATEX zones
  • Run without extraction, with covered air inlets, or on an unstable surface
  • Modify or embed the machine without written Netalux consent
  • Allow untrained operators or skip PPE and zone demarcation
  • Use as a heat gun, ignition source, cutter, or welder
  • Fire into thin air or onto translucent surfaces
  • Crush cables or stand on the fiber or power cord

Turning on and using the machine

Fill coolers correctly before first use (check with the machine off). Complete safety training and prepare the room before these steps.

Startup steps

  • 1. Unpack onto a stable surface.
  • 2. Park the handset with the head aimed safely (prefer about 45°); not at ground, people, or flammables.
  • 3-4. Connect power and plug into the three-phase socket; confirm the power LED.
  • 5. Connect compressed air.
  • 6. Key switch quarter turn right to start.
  • 7. Wait for the home page; lights and reset buttons green when ready to reset.
  • 8. Confirm e-stops are in the normal position.
  • 9. Put on laser safety glasses before arming.
  • 10. Arm on the UI (ready-for-emission: orange continuous lights, headlight on, air cooling the handset).
  • 11. Aim at the work at the correct distance, lens, and angle.
  • 12. Unlock and press the control button to emit (lights flash orange).
  • 14. Change jobs only after releasing the control button.
  • 15. Rotate the head only with the latch unlocked and a clear, safe beam path.

Switching off, head angle, and lenses

Shut down in order. Do not yank power while the display is still on.

Shutdown steps

  • 1. Release the control button.
  • 2. Disarm with the red arm button.
  • 3. When lights are green, turn the key left and remove it.
  • 4. Wait until display and lights are fully off, then unplug power.
  • 5. Disconnect power and compressed air (air may release violently).
  • 6. Clean the protective glass if dirty.
  • 7. Store fiber and handset in the compartment.

Rotatable head and lenses

Slide the latch outward, turn the head, release the latch. Three built-in lenses set working distance: shorter focus is more aggressive. Retune job settings after a lens change.

DCL pulse priority

Ring and core pulses can be programmed separately. Prefer the ring for larger-spot coating work; prefer the core when you need more abrasive character.

Lifting

Use the four hoisting points with proper straps, or a forklift only at the marked pickup areas.

Maintenance

An orange maintenance alarm shows on-screen detail. Contact Netalux Support (support@netalux.com, +32 11 661 882) if basic steps do not clear it. Only Netalux or authorized parties may repair or perform major maintenance.

Protective glass

Clean with Netalux wipes as soil builds. Replace scratched or uncleared glass. Do not use other solvents that attack the coating. Do not laser through dirty glass.

Internal optics

Mirrors and lenses need a Netalux or certified check every six months.

Filters

  • Dust mats behind side panels: replace at least every 6 months
  • Compressed-air stack: prefilters yearly; fine filters CON00010 / CON00011 per display; carbon CON000204 yearly
  • Optics cooler filter CON00089 and DI cartridge per conductivity warnings
  • Source cooler uses biocide water (no DI); flush with Nalco CCL2567 before filter change when prompted; refill with Nalco CCL105 / DI

Acceptance, storage, and transport

Inspect the shipment before first use.

Included items

  • User manual
  • Laser unit, handset, and fiber
  • Extra plugs and power cord
  • Key
  • Cleaning set
  • Laser safety glasses

Storage and moves

Power off fully. Store handset and fiber in the compartment. Clean with mild soap; use isopropanol on protective glass only. Store frost-free, condensation-free, max 40 °C. Drain coolers before freeze risk. IP53 applies upright; protect openings if the unit lies down.

Accessories

Extraction, air, and PPE are part of safe operation, not optional extras.

Vacuum and compressor

Vacuum and compressor
Vacuum suggestion (non-binding)more than 3 kW and about 23 kPa underpressure; 50 mm tube to the handset extractor
Compressed aircold and dry; minimum 6 bar and 3 hp / 2.2 kW
—Air cools optics and keeps the protective glass clear

PPE and screens

Wear EN207 glasses for 1064 nm at this machine power, plus hearing protection and any respiratory gear from the risk analysis. Demarcate with a laser safety screen that meets EN 60825-4.

Troubleshooting alarms

Seven symbols sit on the right of the HMI: General, Maintenance, Temperature, Power supply, Cooling, Humidity, and Compressed air. Orange or blue is non-critical; red disables the machine until you clear the display steps.

Common meanings

Common meanings
General orange/redfollow on-screen text or call Netalux Support
Maintenance orangeschedule service with Netalux Support
Temperature blue/orangewait for warm-up or cool-down; red: critical heat, call Support
Power supply reddefective supply, call Support
Cooling blue/orangewait for cooler temperature; red: cooler fault, call Support
Humidity orangestop and move to a drier room
Compressed air orangecheck filters, pressure, and connection
Message on screen with no lit symbolfollow the display or call Support

EC Declaration of Conformity

Manufacturer declaration for the photographed manual copy (serial blank on that page).

Summary

  • Manufacturer: NV Netalux, De Weven 13, 3583 Paal, Belgium
  • Generic name NX2; model Dagger; type Dagger 4 kW; commercial name Dagger
  • Machinery Directive 2006/42/EG and EMC Directive 2014/30/EU
  • Standards include EN ISO 12100, EN 55011, EN 61326-1, EN 60204-1, EN 60825-1
  • Signed Paal, Belgium, 5 January 2026, Emmanuel Flaam, CEO