Skip to main content

cleanLASER CL1000 Laser Cleaning Parameters

cleanLASER / IPG, "High Power Laser Systems — CL 1000, CL 2000, CL 1000iF", Clean-Lasersysteme GmbH cleanlaser.de (opens in new tab)

The CL1000 is where cleanLASER's high-power line begins, a 1000 W continuous-wave cabinet run through average power and scan speed instead of pulse settings. This continuous output gives up fine control for coverage, so the cabinet belongs on broad, heavy parts such as large weld-prep cleaning jobs.

I'm from cleanLASER and want to update this data

Published values come from public manufacturer datasheets and product pages. If you represent cleanLASER and see an error, outdated figure, or missing model, send a short correction with a public source URL and we will review it.

  • Company name and your role
  • Machine model and the field to change
  • Correct value and units
  • Link to the official product page or datasheet

Email info@z-beam.com · Contact form

Published Specifications

BrandcleanLASER
ModelCL1000
OriginGermany
Laser typeCW diode-pumped fiber
Wavelength1064 nm
Average power1000 W
CoolingWater (water-water or air-water)
Weight490 kg
Beam quality (M²)< 1.1
Operating temp.5–40 °C
CertificationsCE
Sources(1 reference)
  1. https://www.cleanlaser.de/en/products/lasers/high-power-laser-systems/ cleanlaser.de (opens in new tab)

Parameter ranges

cleanLASER CL1000 positioned against other cleanLASER machines. Orange/blue = this model; slate band = cleanLASER min–max for that property. Missing properties are omitted.

Parameter rangesAvg Power1,000 WWeight490.0 kgBeam Quality M²1.10 Operating Temp.5.00 °C40.0 °CPublished datasheetcleanLASER range
Each row is scaled to the cleanLASER lineup max for that property (not a shared multi-unit axis). Validate against machine calibration before production use.

Pulse energy on cleanLASER

CL1000 highlighted among cleanLASER systems with datasheet max pulse energy (mJ). Color = architecture.

Parity basis: datasheet max pulse energy (mJ) only · pulsed · ~1064 nm · shared contaminant thresholds · modeled spot (not a certified cross-OEM test).0.007.5152330cleanLASER CL 500: 25 mJ · Q-HEcleanLASER CL 50025 mJ · Q-HEcleanLASER CL1000iF: 10 mJ · Q-stdcleanLASER CL1000iF10 mJ · Q-std
  • Q-HE
  • Q-std
  • MOPA
  • CW
Parity basis: datasheet max pulse energy (mJ) only · pulsed · ~1064 nm · shared contaminant thresholds · modeled spot (not a certified cross-OEM test).

Fleet Power vs. Pulse Energy

Where the cleanLASER CL1000 sits among 52 laser-cleaning machines with published power and pulse energy. Log-scale axes; shape = architecture; orange highlight = this machine.

Scatter plot of machine max power versus pulse energy104050801001602503206401.0k1.3k1.3k2.6k124581016253264100125128256Max Power (W)Pulse Energy (mJ)Netalux Jango®: 200 W, 100 mJcleanLASER CL1000iF: 1000 W, 10 mJPULSAR Laser SHARK P CL 100M: 100 W, 1.5 mJPULSAR Laser SHARK P CL 200M: 200 W, 1.5 mJPULSAR Laser SHARK P CL 300M: 300 W, 1.5 mJPULSAR Laser SHARK P CL 500A: 500 W, 1.5 mJPULSAR Laser SHARK P CL 1000A: 1000 W, 1.5 mJLaserax LXQ-UHP Series (500W–3kW): 1750 W, 100 mJ4JET JETLASER M200: 200 W, 10 mJ4JET JETLASER M500: 500 W, 100 mJ4JET JETLASER M1000: 1000 W, 100 mJSenFeng SF500HC: 500 W, 50 mJSenFeng SF1000HC: 1000 W, 50 mJHan's Laser HC-PD: 125 W, 1.5 mJP-Laser QF-500: 500 W, 50 mJP-Laser QF-1000: 1000 W, 100 mJP-Laser QF-2000: 2000 W, 100 mJPowerlase Vulcan 500c: 500 W, 40 mJPowerlase FL-C100C: 100 W, 5 mJJNCT Laser 100W Air Cooling Laser Cleaning Machine: 100 W, 1 mJJNCT Laser 200W Air Cooling Laser Cleaning Machine: 200 W, 1 mJWuhan Sintec STPL-V-i500C: 500 W, 60 mJWuhan Sintec STPL-V-i1600: 1600 W, 250 mJHan's Laser HC-PD 50W: 50 W, 1.1 mJHan's Laser HC-PD 100W: 100 W, 1.5 mJHan's Laser HC-PD 200W: 200 W, 1.5 mJNetalux Needle 100: 100 W, 1 mJNetalux Needle 150: 150 W, 1 mJNetalux Needle 200: 200 W, 2 mJNetalux Needle 300: 300 W, 2 mJcleanLASER CL 500: 500 W, 25 mJP-Laser QFC-50: 50 W, 1 mJP-Laser QFC-100: 100 W, 1 mJP-Laser QFC-200: 200 W, 1 mJP-Laser QFC-300: 300 W, 1 mJLaserax LXQ-UHP 500W: 500 W, 100 mJLaserax LXQ-UHP 1000W: 1000 W, 100 mJLaserax LXQ-UHP 2000W: 2000 W, 150 mJLaserax LXQ-UHP 3000W: 3000 W, 150 mJFortune Laser FL-C200: 200 W, 2 mJFortune Laser FL-C300: 300 W, 2 mJP-Laser ECO-C 200: 200 W, 1 mJP-Laser ECO-C 500: 500 W, 1.5 mJNetalux Kamino 300: 300 W, 50 mJNarran ROD 300 Air: 300 W, 15 mJNarran ROD 500: 500 W, 50 mJNarran ROD 1000: 1000 W, 50 mJNarran ROD 2000: 2000 W, 100 mJNarran ROD 100 Air: 100 W, 1.54 mJNarran ROD 500 Bright+: 500 W, 100 mJNarran ROD 1000 Bright+: 1000 W, 100 mJNarran ROD 2000 Bright+: 2000 W, 100 mJ
Fleet power vs. pulse energy data
MachineMax Power (W)Pulse Energy (mJ)
Netalux Jango®200100
cleanLASER CL1000iF100010
PULSAR Laser SHARK P CL 100M1001.5
PULSAR Laser SHARK P CL 200M2001.5
PULSAR Laser SHARK P CL 300M3001.5
PULSAR Laser SHARK P CL 500A5001.5
PULSAR Laser SHARK P CL 1000A10001.5
Laserax LXQ-UHP Series (500W–3kW)1750100
4JET JETLASER M20020010
4JET JETLASER M500500100
4JET JETLASER M10001000100
SenFeng SF500HC50050
SenFeng SF1000HC100050
Han's Laser HC-PD1251.5
P-Laser QF-50050050
P-Laser QF-10001000100
P-Laser QF-20002000100
Powerlase Vulcan 500c50040
Powerlase FL-C100C1005
JNCT Laser 100W Air Cooling Laser Cleaning Machine1001
JNCT Laser 200W Air Cooling Laser Cleaning Machine2001
Wuhan Sintec STPL-V-i500C50060
Wuhan Sintec STPL-V-i16001600250
Han's Laser HC-PD 50W501.1
Han's Laser HC-PD 100W1001.5
Han's Laser HC-PD 200W2001.5
Netalux Needle 1001001
Netalux Needle 1501501
Netalux Needle 2002002
Netalux Needle 3003002
cleanLASER CL 50050025
P-Laser QFC-50501
P-Laser QFC-1001001
P-Laser QFC-2002001
P-Laser QFC-3003001
Laserax LXQ-UHP 500W500100
Laserax LXQ-UHP 1000W1000100
Laserax LXQ-UHP 2000W2000150
Laserax LXQ-UHP 3000W3000150
Fortune Laser FL-C2002002
Fortune Laser FL-C3003002
P-Laser ECO-C 2002001
P-Laser ECO-C 5005001.5
Netalux Kamino 30030050
Narran ROD 300 Air30015
Narran ROD 50050050
Narran ROD 1000100050
Narran ROD 20002000100
Narran ROD 100 Air1001.54
Narran ROD 500 Bright+500100
Narran ROD 1000 Bright+1000100
Narran ROD 2000 Bright+2000100
  • MOPA
  • Q-HE
  • Q-std
← cleanLASER systems

Specifications sourced from manufacturer datasheets. Values are reference data — validate against your machine's actual calibration before production use.

Buyer questions about cleanLASER CL1000

  • How does the CL1000 differ from the CL1000iF at the same 1000 W rating?

    The CL1000 runs as a continuous-wave thermal source where average power and scan speed are the primary controls, with no pulse width or repetition-rate dial. The CL1000iF keeps the same average power class but fires Q-switched pulses for selective automated work. Choose the CL1000 w[1]hen the job needs sustained large-area heating rather than pulsed spallation.

  • Why is the CL1000 water-cooled and nearly half a tonne?

    A 1000 W[1] continuous beam dumps heat that air-cooled handheld cabinets cannot reject for long duty cycles. The published cabinet weighs about 490 kg with water-water or air-water cooling so the source can hold power on large panels without thermal foldback. Plan floor space, three-phase power, and coolant before delivery, because this is a mobile industrial cabinet rather than a suitcase laser.

  • Which jobs fit the CL1000 in the cleanLASER high-power line?

    Manufacturer positioning for the CL1000 points to nuclear decontamination, large-area paint and rust stripping, mold cleaning, and weld-seam prep where a continuous 1000 W[1] top-hat beam can cover thick layers. Thin precision films and heat-sensitive coupons usually belong on a pulsed sibling, because the CL1000 is the thermal workhorse for area and adhesion rather than fine selective finishing.

  • What facility power and footprint does the CL1000 need?

    The published cabinet draws about 6.5 kVA on a 3×16A, 400 V 50/60 Hz supply and measures roughly 1600 × 760 × 1270 mm at about 490 kg. Operating ambient stays between 5 and 40 °C with water cooling online. Plan three-phase power, floor space, and coolant before delivery rather than treating it like a plug-in handheld unit.

Sources(1 reference)
  1. cleanLASER / IPG, "High Power Laser Systems — CL 1000, CL 2000, CL 1000iF", Clean-Lasersysteme GmbH cleanlaser.de (opens in new tab) — 1000 W continuous-wave beam source power