Skip to main content

cleanLASER CL1000

Continuous Wave (CW) · Germany — CW diode-pumped fiber — No pulse width or frequency parameter. Steady emission. Cleaning is entirely thermal. High area rates; significant substrate heating risk. — CW architecture — no pulse width or frequency parameters. Primary operator controls are power level and scan speed. Cleaning mechanism is thermal (Regime 3).

cleanLASER CL1000 · Parameter RangesAvg Power1,000 WFluenceData not availableSpot Diameter3.00 mm20.0 mmScan Speed500.0 mm/s5,000 mm/sPublished manufacturer specAblation threshold (researched)Calculated from physics

Published Specifications

BrandcleanLASER
ModelCL1000
OriginGermany
Laser typeCW diode-pumped fiber
Wavelength1064 nm
Average power1000 W
CoolingWater (water-water or air-water)
Weight490 kg
Beam quality (M²)< 1.1
Operating temp.5–40 °C
CertificationsCE

Source: https://www.cleanlaser.de/en/products/lasers/high-power-laser-systems/

Compatible Material Pages

Laser cleaning parameters for common materials processed by fiber laser systems.

← All machines

Specifications sourced from manufacturer datasheets. Values are reference data — validate against your machine's actual calibration before production use.