On-Site Demo
- CoversCoverage SF Bay Area
- Test your material
Laser cleaning machine hub p.1 maxwavelaser.com (opens in new tab)
Heavy scale on big steel parts is the job for the 2000W CW, which doubles the output of the smaller MaxWave cabinet for shops that need more area per shift. This continuous-wave cabinet runs on power and scan speed below the 3000 W unit, so its steady beam suits weld-prep cleaning on heat-tolerant steel.
Published values come from public manufacturer datasheets and product pages. If you represent MaxWave Laser and see an error, outdated figure, or missing model, send a short correction with a public source URL and we will review it.
Entity-fact-cited specifications for the MaxWave Laser MaxWave 2000W CW sourced from the canonical machines entity registry. Each row is anchored to a citation.
| Brand | MaxWave Laser |
| Model | MaxWave 2000W CW |
| Origin | China |
| Laser type | CW fiber |
| Wavelength | 1064 nm |
| Average power | 2000 W |
| Cooling | Water |
MaxWave Laser MaxWave 2000W CW positioned against other MaxWave Laser machines. Orange/blue = this model; slate band = MaxWave Laser min–max for that property. Missing properties are omitted.
Where the MaxWave Laser MaxWave 2000W CW sits among 52 laser-cleaning machines with published power and pulse energy. Log-scale axes; shape = architecture; orange highlight = this machine.
| Machine | Max Power (W) | Pulse Energy (mJ) |
|---|---|---|
| Netalux Jango® | 200 | 100 |
| cleanLASER CL1000iF | 1000 | 10 |
| PULSAR Laser SHARK P CL 100M | 100 | 1.5 |
| PULSAR Laser SHARK P CL 200M | 200 | 1.5 |
| PULSAR Laser SHARK P CL 300M | 300 | 1.5 |
| PULSAR Laser SHARK P CL 500A | 500 | 1.5 |
| PULSAR Laser SHARK P CL 1000A | 1000 | 1.5 |
| Laserax LXQ-UHP Series (500W–3kW) | 1750 | 100 |
| 4JET JETLASER M200 | 200 | 10 |
| 4JET JETLASER M500 | 500 | 100 |
| 4JET JETLASER M1000 | 1000 | 100 |
| SenFeng SF500HC | 500 | 50 |
| SenFeng SF1000HC | 1000 | 50 |
| Han's Laser HC-PD | 125 | 1.5 |
| P-Laser QF-500 | 500 | 50 |
| P-Laser QF-1000 | 1000 | 100 |
| P-Laser QF-2000 | 2000 | 100 |
| Powerlase Vulcan 500c | 500 | 40 |
| Powerlase FL-C100C | 100 | 5 |
| JNCT Laser 100W Air Cooling Laser Cleaning Machine | 100 | 1 |
| JNCT Laser 200W Air Cooling Laser Cleaning Machine | 200 | 1 |
| Wuhan Sintec STPL-V-i500C | 500 | 60 |
| Wuhan Sintec STPL-V-i1600 | 1600 | 250 |
| Han's Laser HC-PD 50W | 50 | 1.1 |
| Han's Laser HC-PD 100W | 100 | 1.5 |
| Han's Laser HC-PD 200W | 200 | 1.5 |
| Netalux Needle 100 | 100 | 1 |
| Netalux Needle 150 | 150 | 1 |
| Netalux Needle 200 | 200 | 2 |
| Netalux Needle 300 | 300 | 2 |
| cleanLASER CL 500 | 500 | 25 |
| P-Laser QFC-50 | 50 | 1 |
| P-Laser QFC-100 | 100 | 1 |
| P-Laser QFC-200 | 200 | 1 |
| P-Laser QFC-300 | 300 | 1 |
| Laserax LXQ-UHP 500W | 500 | 100 |
| Laserax LXQ-UHP 1000W | 1000 | 100 |
| Laserax LXQ-UHP 2000W | 2000 | 150 |
| Laserax LXQ-UHP 3000W | 3000 | 150 |
| Fortune Laser FL-C200 | 200 | 2 |
| Fortune Laser FL-C300 | 300 | 2 |
| P-Laser ECO-C 200 | 200 | 1 |
| P-Laser ECO-C 500 | 500 | 1.5 |
| Netalux Kamino 300 | 300 | 50 |
| Narran ROD 300 Air | 300 | 15 |
| Narran ROD 500 | 500 | 50 |
| Narran ROD 1000 | 1000 | 50 |
| Narran ROD 2000 | 2000 | 100 |
| Narran ROD 100 Air | 100 | 1.54 |
| Narran ROD 500 Bright+ | 500 | 100 |
| Narran ROD 1000 Bright+ | 1000 | 100 |
| Narran ROD 2000 Bright+ | 2000 | 100 |
The MaxWave 2000W[1] CW is the middle continuous-wave cabinet, with 2000 W of average power between the 1000W CW and the 3000W CW. Doubling the 1000W CW output lets the MaxWave 2000W CW cover more area per stroke on the same coating, while the 3000W CW is held back for the thickest buildup in the MaxWave range.
Average power and scan speed are the two controls on the MaxWave 2000W[1] CW, because its continuous 1064 nm fiber beam has no pulse width or repetition rate to set. Slowing the scan on the MaxWave 2000W CW pushes more energy into each spot, so scan speed is the main lever when a coating resists or the base metal starts to discolor.
Large steel surfaces under thick rust, mill scale or old paint are the jobs that justify the MaxWave 2000W[1] CW, which matches industry guidance pairing CW sources with heavy rust over large areas (Dyna Laser guide). Fine molds, thin sheet and heat-sensitive finishes are a poor match for 2000 W of continuous output, and those jobs belong on a pulsed MaxWave model instead.
Yes, the MaxWave 2000W[1] CW is water cooled, like every continuous-wave cabinet MaxWave lists. Leave room for the chiller and its water supply next to the MaxWave 2000W CW, and check the chiller before long runs, since a 2000 W source sheds far more heat than the air-cooled 100W and 200W Pulse units.
The MaxWave 2000W[1] CW can overheat thin metal, because a continuous 2000 W beam keeps heating the part between strokes instead of resting between pulses. Thin sheet on the MaxWave 2000W CW calls for a faster scan, a lower power setting and a trial on a scrap piece of the same gauge before the real part goes under the beam.
The governing class for the MaxWave 2000W[1] CW is the one on its label and its CDRH or CE file, so safety planning starts from that record. Open handheld fiber cleaners are generally handled as Class 4 (Laser Photonics guide), and at 2000 W the MaxWave 2000W CW calls for rated eyewear, a closed-off zone and trained operators before the beam is switched on.