cleanLASER CL 500iM

Standard Q-Switched · Germany — Q-switched nanosecond fiber — Fixed pulse width (typically 80–200 ns), adjustable frequency within narrower range than MOPA. Lower pulse energy ceiling than high-energy Q-switched.

cleanLASER CL 500iM · Parameter RangesAvg Power500.0 WFluenceData not availableFrequency50.0 kHz200.0 kHzPulse Width120.0 nsSpot DiameterData not availableScan SpeedData not availablePublished manufacturer specAblation threshold (researched)Calculated from physics

Derived Parameters

Peak power83.3 kW
Fluence at 2 mm spot0.318 J/cm²
Fluence at 5 mm spot0.0509 J/cm²
Overlap (cleaning)60–80%

Field spot diameter varies by scan head — 2 mm and 5 mm are representative values for handheld cleaning heads.

Derived from manufacturer pulse energy data. Spot size varies by scan head — validate against your calibration.

Published Specifications

BrandcleanLASER
ModelCL 500iM
OriginGermany
Laser typeQ-switched nanosecond fiber
Wavelength1064 nm
Average power500 W
Pulse width120 ns (fixed)
Pulse frequency50–500 kHz
CoolingAir
Beam quality (M²)< 1.6

Source: https://adapt-laser.com/product/cl500im/

Compatible Material Pages

Laser cleaning parameters for common materials processed by fiber laser systems.

← All machines

Specifications sourced from manufacturer datasheets. Values are reference data — validate against your machine's actual calibration before production use.