On-Site Demo
- CoversCoverage SF Bay Area
- Test your material
CL 500iM adapt-laser.com (opens in new tab)
Hand-guided work on fabricated steel is the reason cleanLASER put 500 W behind a 120 ns pulse in the CL 500iM. That pulse class lifts weld oxide, rust, and paint at a pace a smaller head cannot hold, while keeping heat out of the part.
Published values come from public manufacturer datasheets and product pages. If you represent cleanLASER and see an error, outdated figure, or missing model, send a short correction with a public source URL and we will review it.
| Peak power | 83.3 kW |
| Fluence at 2 mm spot | 0.318 J/cm² |
| Fluence at 5 mm spot | 0.0509 J/cm² |
| Overlap (cleaning) | 60–80% |
Entity-fact-cited specifications for the cleanLASER CL 500iM sourced from the canonical machines entity registry. Each row is anchored to a citation.
| Brand | cleanLASER |
| Model | CL 500iM |
| Origin | Germany |
| Laser type | Q-switched nanosecond fiber |
| Wavelength | 1064 nm |
| Average power | 500 W |
| Pulse width | 120 ns |
| Pulse frequency | 50–500 kHz |
| Cooling | Air |
| Beam quality (M²) | < 1.6 |
cleanLASER CL 500iM positioned against other cleanLASER machines. Orange/blue = this model; slate band = cleanLASER min–max for that property. Missing properties are omitted.
CL 500iM highlighted among cleanLASER systems with datasheet max pulse energy (mJ). Color = architecture.
Where the cleanLASER CL 500iM sits among 52 laser-cleaning machines with published power and pulse energy. Log-scale axes; shape = architecture; orange highlight = this machine.
| Machine | Max Power (W) | Pulse Energy (mJ) |
|---|---|---|
| Netalux Jango® | 200 | 100 |
| cleanLASER CL1000iF | 1000 | 10 |
| PULSAR Laser SHARK P CL 100M | 100 | 1.5 |
| PULSAR Laser SHARK P CL 200M | 200 | 1.5 |
| PULSAR Laser SHARK P CL 300M | 300 | 1.5 |
| PULSAR Laser SHARK P CL 500A | 500 | 1.5 |
| PULSAR Laser SHARK P CL 1000A | 1000 | 1.5 |
| Laserax LXQ-UHP Series (500W–3kW) | 1750 | 100 |
| 4JET JETLASER M200 | 200 | 10 |
| 4JET JETLASER M500 | 500 | 100 |
| 4JET JETLASER M1000 | 1000 | 100 |
| SenFeng SF500HC | 500 | 50 |
| SenFeng SF1000HC | 1000 | 50 |
| Han's Laser HC-PD | 125 | 1.5 |
| P-Laser QF-500 | 500 | 50 |
| P-Laser QF-1000 | 1000 | 100 |
| P-Laser QF-2000 | 2000 | 100 |
| Powerlase Vulcan 500c | 500 | 40 |
| Powerlase FL-C100C | 100 | 5 |
| JNCT Laser 100W Air Cooling Laser Cleaning Machine | 100 | 1 |
| JNCT Laser 200W Air Cooling Laser Cleaning Machine | 200 | 1 |
| Wuhan Sintec STPL-V-i500C | 500 | 60 |
| Wuhan Sintec STPL-V-i1600 | 1600 | 250 |
| Han's Laser HC-PD 50W | 50 | 1.1 |
| Han's Laser HC-PD 100W | 100 | 1.5 |
| Han's Laser HC-PD 200W | 200 | 1.5 |
| Netalux Needle 100 | 100 | 1 |
| Netalux Needle 150 | 150 | 1 |
| Netalux Needle 200 | 200 | 2 |
| Netalux Needle 300 | 300 | 2 |
| cleanLASER CL 500 | 500 | 25 |
| P-Laser QFC-50 | 50 | 1 |
| P-Laser QFC-100 | 100 | 1 |
| P-Laser QFC-200 | 200 | 1 |
| P-Laser QFC-300 | 300 | 1 |
| Laserax LXQ-UHP 500W | 500 | 100 |
| Laserax LXQ-UHP 1000W | 1000 | 100 |
| Laserax LXQ-UHP 2000W | 2000 | 150 |
| Laserax LXQ-UHP 3000W | 3000 | 150 |
| Fortune Laser FL-C200 | 200 | 2 |
| Fortune Laser FL-C300 | 300 | 2 |
| P-Laser ECO-C 200 | 200 | 1 |
| P-Laser ECO-C 500 | 500 | 1.5 |
| Netalux Kamino 300 | 300 | 50 |
| Narran ROD 300 Air | 300 | 15 |
| Narran ROD 500 | 500 | 50 |
| Narran ROD 1000 | 1000 | 50 |
| Narran ROD 2000 | 2000 | 100 |
| Narran ROD 100 Air | 100 | 1.54 |
| Narran ROD 500 Bright+ | 500 | 100 |
| Narran ROD 1000 Bright+ | 1000 | 100 |
| Narran ROD 2000 Bright+ | 2000 | 100 |
Choose the CL 500iM when the job needs short pulses that keep heat out of the part, since it runs a Q-switched nanosecond fiber source at 500 W[1] with a 120 ns pulse. The CL1000 runs a continuous beam at 1000 W with water cooling, so it gives up that pulse control in exchange for faster area cleaning on heavy stock.
No, the pulse width is fixed at 120 ns on the CL 500iM, so tuning comes from pulse frequency across 50-500 kHz, plus scan speed and spot overlap. At the same average power, a lower frequency puts more energy into each fixed-length pulse, which helps on tougher coatings.
No, the CL 500iM is air cooled, which stands out at 500 W[1] because the CL 500 sibling in the same cleanLASER family needs water cooling. Without a chiller to haul and plumb, the iM is the easier of the two to move between job sites.
The beam is close to ideal, with the data on file listing beam quality at M² 1.6 at a wavelength of 1064 nm, where a perfect beam would read 1.0. A beam that clean focuses to a small, even spot, which helps a hand-guided head hold a consistent track across the surface.
cleanLASER prints Class 4 on its CL 1000 and CL 2000 high power pages, but the CL 500iM page on file does not state a class, so read it from the unit's label. Plan eyewear, a controlled area, and trained operators either way, since open handheld fiber cleaners are generally handled as Class 4 products.
It is built for hand-guided removal of weld oxide, rust, and paint on metal parts where heat input matters, because a 120 ns pulse delivers energy in short bursts instead of a steady beam. For broad areas of heavy rust, the continuous CL1000 or CL2000 is the better match.