cleanLASER CL 500iM
Standard Q-Switched · Germany — Q-switched nanosecond fiber — Fixed pulse width (typically 80–200 ns), adjustable frequency within narrower range than MOPA. Lower pulse energy ceiling than high-energy Q-switched.
Derived Parameters
| Peak power | 83.3 kW |
| Fluence at 2 mm spot | 0.318 J/cm² |
| Fluence at 5 mm spot | 0.0509 J/cm² |
| Overlap (cleaning) | 60–80% |
Field spot diameter varies by scan head — 2 mm and 5 mm are representative values for handheld cleaning heads.
Derived from manufacturer pulse energy data. Spot size varies by scan head — validate against your calibration.
Published Specifications
| Brand | cleanLASER |
| Model | CL 500iM |
| Origin | Germany |
| Laser type | Q-switched nanosecond fiber |
| Wavelength | 1064 nm |
| Average power | 500 W |
| Pulse width | 120 ns (fixed) |
| Pulse frequency | 50–500 kHz |
| Cooling | Air |
| Beam quality (M²) | < 1.6 |
Compatible Material Pages
Laser cleaning parameters for common materials processed by fiber laser systems.
← All machines
Specifications sourced from manufacturer datasheets. Values are reference data — validate against your machine's actual calibration before production use.