Skip to main content

cleanLASER CL 500iM Laser Cleaning Parameters

CL 500iM adapt-laser.com (opens in new tab)

Hand-guided work on fabricated steel is the reason cleanLASER put 500 W behind a 120 ns pulse in the CL 500iM. That pulse class lifts weld oxide, rust, and paint at a pace a smaller head cannot hold, while keeping heat out of the part.

I'm from cleanLASER and want to update this data

Published values come from public manufacturer datasheets and product pages. If you represent cleanLASER and see an error, outdated figure, or missing model, send a short correction with a public source URL and we will review it.

  • Company name and your role
  • Machine model and the field to change
  • Correct value and units
  • Link to the official product page or datasheet

Email info@z-beam.com · Contact form

Derived Parameters

Peak power83.3 kW
Fluence at 2 mm spot0.318 J/cm²
Fluence at 5 mm spot0.0509 J/cm²
Overlap (cleaning)60–80%

Field spot diameter varies by scan head — 2 mm and 5 mm are representative values for handheld cleaning heads.

Derived from manufacturer pulse energy data. Spot size varies by scan head — validate against your calibration.

Published Specifications

BrandcleanLASER
ModelCL 500iM
OriginGermany
Laser typeQ-switched nanosecond fiber
Wavelength1064 nm
Average power500 W
Pulse width120 ns
Pulse frequency50–500 kHz
CoolingAir
Beam quality (M²)< 1.6
Sources(1 reference)
  1. https://adapt-laser.com/product/cl500im/ adapt-laser.com (opens in new tab)

Parameter ranges

cleanLASER CL 500iM positioned against other cleanLASER machines. Orange/blue = this model; slate band = cleanLASER min–max for that property. Missing properties are omitted.

Parameter rangesAvg Power500.0 WFrequency50.0 kHz500.0 kHzPulse Width120.0 nsPeak Power83.3 kWFluence @ 2 mm0.32 J/cm²Fluence @ 5 mm0.05 J/cm²Beam Quality M²1.60 Published datasheetCalculated from physicscleanLASER range
Each row is scaled to the cleanLASER lineup max for that property (not a shared multi-unit axis). Validate against machine calibration before production use.

Pulse energy on cleanLASER

CL 500iM highlighted among cleanLASER systems with datasheet max pulse energy (mJ). Color = architecture.

Parity basis: datasheet max pulse energy (mJ) only · pulsed · ~1064 nm · shared contaminant thresholds · modeled spot (not a certified cross-OEM test).0.007.5152330cleanLASER CL 500: 25 mJ · Q-HEcleanLASER CL 50025 mJ · Q-HEcleanLASER CL1000iF: 10 mJ · Q-stdcleanLASER CL1000iF10 mJ · Q-std
  • Q-HE
  • Q-std
  • MOPA
  • CW
Parity basis: datasheet max pulse energy (mJ) only · pulsed · ~1064 nm · shared contaminant thresholds · modeled spot (not a certified cross-OEM test).

Fleet Power vs. Pulse Energy

Where the cleanLASER CL 500iM sits among 52 laser-cleaning machines with published power and pulse energy. Log-scale axes; shape = architecture; orange highlight = this machine.

Scatter plot of machine max power versus pulse energy104050801001602503206401.0k1.3k1.3k2.6k124581016253264100125128256Max Power (W)Pulse Energy (mJ)Netalux Jango®: 200 W, 100 mJcleanLASER CL1000iF: 1000 W, 10 mJPULSAR Laser SHARK P CL 100M: 100 W, 1.5 mJPULSAR Laser SHARK P CL 200M: 200 W, 1.5 mJPULSAR Laser SHARK P CL 300M: 300 W, 1.5 mJPULSAR Laser SHARK P CL 500A: 500 W, 1.5 mJPULSAR Laser SHARK P CL 1000A: 1000 W, 1.5 mJLaserax LXQ-UHP Series (500W–3kW): 1750 W, 100 mJ4JET JETLASER M200: 200 W, 10 mJ4JET JETLASER M500: 500 W, 100 mJ4JET JETLASER M1000: 1000 W, 100 mJSenFeng SF500HC: 500 W, 50 mJSenFeng SF1000HC: 1000 W, 50 mJHan's Laser HC-PD: 125 W, 1.5 mJP-Laser QF-500: 500 W, 50 mJP-Laser QF-1000: 1000 W, 100 mJP-Laser QF-2000: 2000 W, 100 mJPowerlase Vulcan 500c: 500 W, 40 mJPowerlase FL-C100C: 100 W, 5 mJJNCT Laser 100W Air Cooling Laser Cleaning Machine: 100 W, 1 mJJNCT Laser 200W Air Cooling Laser Cleaning Machine: 200 W, 1 mJWuhan Sintec STPL-V-i500C: 500 W, 60 mJWuhan Sintec STPL-V-i1600: 1600 W, 250 mJHan's Laser HC-PD 50W: 50 W, 1.1 mJHan's Laser HC-PD 100W: 100 W, 1.5 mJHan's Laser HC-PD 200W: 200 W, 1.5 mJNetalux Needle 100: 100 W, 1 mJNetalux Needle 150: 150 W, 1 mJNetalux Needle 200: 200 W, 2 mJNetalux Needle 300: 300 W, 2 mJcleanLASER CL 500: 500 W, 25 mJP-Laser QFC-50: 50 W, 1 mJP-Laser QFC-100: 100 W, 1 mJP-Laser QFC-200: 200 W, 1 mJP-Laser QFC-300: 300 W, 1 mJLaserax LXQ-UHP 500W: 500 W, 100 mJLaserax LXQ-UHP 1000W: 1000 W, 100 mJLaserax LXQ-UHP 2000W: 2000 W, 150 mJLaserax LXQ-UHP 3000W: 3000 W, 150 mJFortune Laser FL-C200: 200 W, 2 mJFortune Laser FL-C300: 300 W, 2 mJP-Laser ECO-C 200: 200 W, 1 mJP-Laser ECO-C 500: 500 W, 1.5 mJNetalux Kamino 300: 300 W, 50 mJNarran ROD 300 Air: 300 W, 15 mJNarran ROD 500: 500 W, 50 mJNarran ROD 1000: 1000 W, 50 mJNarran ROD 2000: 2000 W, 100 mJNarran ROD 100 Air: 100 W, 1.54 mJNarran ROD 500 Bright+: 500 W, 100 mJNarran ROD 1000 Bright+: 1000 W, 100 mJNarran ROD 2000 Bright+: 2000 W, 100 mJ
Fleet power vs. pulse energy data
MachineMax Power (W)Pulse Energy (mJ)
Netalux Jango®200100
cleanLASER CL1000iF100010
PULSAR Laser SHARK P CL 100M1001.5
PULSAR Laser SHARK P CL 200M2001.5
PULSAR Laser SHARK P CL 300M3001.5
PULSAR Laser SHARK P CL 500A5001.5
PULSAR Laser SHARK P CL 1000A10001.5
Laserax LXQ-UHP Series (500W–3kW)1750100
4JET JETLASER M20020010
4JET JETLASER M500500100
4JET JETLASER M10001000100
SenFeng SF500HC50050
SenFeng SF1000HC100050
Han's Laser HC-PD1251.5
P-Laser QF-50050050
P-Laser QF-10001000100
P-Laser QF-20002000100
Powerlase Vulcan 500c50040
Powerlase FL-C100C1005
JNCT Laser 100W Air Cooling Laser Cleaning Machine1001
JNCT Laser 200W Air Cooling Laser Cleaning Machine2001
Wuhan Sintec STPL-V-i500C50060
Wuhan Sintec STPL-V-i16001600250
Han's Laser HC-PD 50W501.1
Han's Laser HC-PD 100W1001.5
Han's Laser HC-PD 200W2001.5
Netalux Needle 1001001
Netalux Needle 1501501
Netalux Needle 2002002
Netalux Needle 3003002
cleanLASER CL 50050025
P-Laser QFC-50501
P-Laser QFC-1001001
P-Laser QFC-2002001
P-Laser QFC-3003001
Laserax LXQ-UHP 500W500100
Laserax LXQ-UHP 1000W1000100
Laserax LXQ-UHP 2000W2000150
Laserax LXQ-UHP 3000W3000150
Fortune Laser FL-C2002002
Fortune Laser FL-C3003002
P-Laser ECO-C 2002001
P-Laser ECO-C 5005001.5
Netalux Kamino 30030050
Narran ROD 300 Air30015
Narran ROD 50050050
Narran ROD 1000100050
Narran ROD 20002000100
Narran ROD 100 Air1001.54
Narran ROD 500 Bright+500100
Narran ROD 1000 Bright+1000100
Narran ROD 2000 Bright+2000100
  • MOPA
  • Q-HE
  • Q-std
← cleanLASER systems

Specifications sourced from manufacturer datasheets. Values are reference data — validate against your machine's actual calibration before production use.

cleanLASER CL 500iM questions

  • Should I choose the cleanLASER CL 500iM or the CL1000?

    Choose the CL 500iM when the job needs short pulses that keep heat out of the part, since it runs a Q-switched nanosecond fiber source at 500 W[1] with a 120 ns pulse. The CL1000 runs a continuous beam at 1000 W with water cooling, so it gives up that pulse control in exchange for faster area cleaning on heavy stock.

  • Can I change the pulse width on the CL 500iM?

    No, the pulse width is fixed at 120 ns on the CL 500iM, so tuning comes from pulse frequency across 50-500 kHz, plus scan speed and spot overlap. At the same average power, a lower frequency puts more energy into each fixed-length pulse, which helps on tougher coatings.

  • Does the CL 500iM need a water chiller?

    No, the CL 500iM is air cooled, which stands out at 500 W[1] because the CL 500 sibling in the same cleanLASER family needs water cooling. Without a chiller to haul and plumb, the iM is the easier of the two to move between job sites.

  • How tight is the beam on the CL 500iM?

    The beam is close to ideal, with the data on file listing beam quality at M² 1.6 at a wavelength of 1064 nm, where a perfect beam would read 1.0. A beam that clean focuses to a small, even spot, which helps a hand-guided head hold a consistent track across the surface.

  • What laser class does cleanLASER give its cleaning systems?

    cleanLASER prints Class 4 on its CL 1000 and CL 2000 high power pages, but the CL 500iM page on file does not state a class, so read it from the unit's label. Plan eyewear, a controlled area, and trained operators either way, since open handheld fiber cleaners are generally handled as Class 4 products.

  • What jobs is the CL 500iM built for?

    It is built for hand-guided removal of weld oxide, rust, and paint on metal parts where heat input matters, because a 120 ns pulse delivers energy in short bursts instead of a steady beam. For broad areas of heavy rust, the continuous CL1000 or CL2000 is the better match.

Sources(3 references)
  1. cl500im-adapt-specs adapt-laser.com (opens in new tab) — CL 500iM: 500 W, 120 ns pulse, 50-500 kHz, M² 1.6, air cooled
  2. cleanlaser-high-power-class4 cleanlaser.de (opens in new tab) — CL 1000 and CL 2000 high power pages state Class 4 laser
  3. handheld-fiber-class4 laserphotonics.com (opens in new tab) — Open handheld fiber cleaners are treated as Class 4 products