Han's Laser Laser Cleaning Machines

HC-PD Pulse Mini Portable Laser Cleaner hanslaserus.com (opens in new tab)

Han's Laser splits the HC line between a water-cooled 2000 W continuous-wave HC-D built for thermal swath cleaning and an HC-PD pulsed ladder from a 7.8 kg 50 W air-cooled entry through a 300 W air-cooled MOPA and water-cooled 500 W and 1000 W MOPA heads. The HC-D publishes a 750 mm scan swath with six wobble patterns. Published pulse energy on pulsed units spans 1.1-1.5 mJ across eight complete systems from China.

I'm from Han's Laser and want to update this data

Published values come from public manufacturer datasheets and product pages. If you represent Han's Laser and see an error, outdated figure, or missing model, send a short correction with a public source URL and we will review it.

  • Company name and your role
  • Machine model and the field to change
  • Correct value and units
  • Link to the official product page or datasheet

Email info@z-beam.com · Contact form

Published weight and cooling

ModelWeightCooling
HC-PD15.5 kgAir
HC-PD 50W7.8 kgAir
HC-PD 100W10.5 kgAir
HC-PD 200W15.5 kgAir

Pulse energy on Han's Laser

Datasheet max pulse energy (mJ) for complete systems in this brand. Color = source architecture. Click a name for machine detail.

Pulse energy on Han's Laser0.000.501.01.52.0Han's Laser HC-PD 200W: 1.5 mJ · Q-stdHan's Laser HC-PD 200W1.5 mJ · Q-stdHan's Laser HC-PD: 1.5 mJ · Q-stdHan's Laser HC-PD1.5 mJ · Q-stdHan's Laser HC-PD 100W: 1.5 mJ · Q-stdHan's Laser HC-PD 100W1.5 mJ · Q-stdHan's Laser HC-PD 50W: 1.1 mJ · Q-stdHan's Laser HC-PD 50W1.1 mJ · Q-std
  • Q-HE
  • Q-std
  • MOPA
  • CW
Parity basis: datasheet max pulse energy (mJ) only · pulsed · ~1064 nm · shared contaminant thresholds · modeled spot (not a certified cross-OEM test).
Model
→
→
→
→
→
→
→
→

Han's Laser cooling and architecture

  • When does Han's Laser move from air cooling to a water chiller?

    Air cooling covers the HC-PD 50 W, 100 W, 200 W, and 300 W units. The HC-PD 500, HC-PD 1000, and the 2000 W HC-D require water cooling for sustained duty.

  • How does the HC-D differ from the HC-PD pulsed models?

    The HC-D is a 2000 W continuous-wave thermal cleaner with a 750 mm scan swath, while HC-PD models are pulsed (Q-switched or MOPA) with published pulse energy of 1.1-1.5 mJ for substrate-selective work.

I'm from Han's Laser and want to update this data

Published values come from public manufacturer datasheets and product pages. If you represent Han's Laser and see an error, outdated figure, or missing model, send a short correction with a public source URL and we will review it.

  • Company name and your role
  • Machine model and the field to change
  • Correct value and units
  • Link to the official product page or datasheet

Email info@z-beam.com · Contact form