Skip to main content

P-Laser QFC-300 Laser Cleaning Parameters

QF-Compact 200-300 W p-laser.com (opens in new tab)

Three hundred watts is as far as P-Laser takes its Compact range, giving the QFC-300 the fastest coverage of any unit that keeps the shared 100 ns pulse. Shops reach for this unit on in-situ mould and weld cleaning when the slower QFC-200 cannot keep up with the cycle.

I'm from P-Laser and want to update this data

Published values come from public manufacturer datasheets and product pages. If you represent P-Laser and see an error, outdated figure, or missing model, send a short correction with a public source URL and we will review it.

  • Company name and your role
  • Machine model and the field to change
  • Correct value and units
  • Link to the official product page or datasheet

Email info@z-beam.com · Contact form

Derived Parameters

Fluence at 2 mm spot0.0318 J/cm²
Fluence at 5 mm spot0.00509 J/cm²
Overlap (cleaning)60–80%

Field spot diameter varies by scan head — 2 mm and 5 mm are representative values for handheld cleaning heads.

Derived from published specifications.

Canonical Specifications

Entity-fact-cited specifications for the P-Laser QFC-300 sourced from the canonical machines entity registry. Each row is anchored to a citation.

P-Laser QFC-300Standard Q-Switched
Published specifications for P-Laser QFC-300
Max Power300 W[1],[2]
Pulse Energy1 mJ[1],[2]
Pulse Duration100 ns[1],[2]
Repetition Rate20–200 kHz[1],[2]
Beam Quality (M²)2[3]
Cooling MethodAir[4],[5],[6]
WeightWeight: 30 - 35 kg[7]
Sources(7 references)
  1. The theory and application of nanosecond Laser surface treatment technology: A review journals.sagepub.com (opens in new tab)
  2. Research Progress and Challenges in Laser-Controlled Coating Removal pmc.ncbi.nlm.nih.gov (opens in new tab)
  3. M² Factor (Beam Quality Factor) — RP Photonics Encyclopedia rp-photonics.com (opens in new tab)
  4. Laser Cooling Units — RP Photonics Encyclopedia rp-photonics.com (opens in new tab)
  5. Guidance on Laser Safety Requirements (DOE EFCOG Laser Safety Community of Practice, 2023) efcog.org (opens in new tab)
  6. QF-Compact 200-300 W p-laser.com (opens in new tab)

Published Specifications

BrandP-Laser
ModelQFC-300
OriginBelgium
Laser typeQ-switched nanosecond pulsed fiber
Wavelength1064 nm
Average power300 W
Max pulse energy1 mJ
Pulse width100 ns
Pulse frequency20–200 kHz
CoolingAir
Beam quality (M²)< 1.6
Sources(1 reference)
  1. https://www.p-laser.com/products/qf-compact-200-300-w p-laser.com (opens in new tab)

Parameter ranges

P-Laser QFC-300 positioned against other P-Laser machines. Orange/blue = this model; slate band = P-Laser min–max for that property. Missing properties are omitted.

Parameter rangesAvg Power300.0 WPulse Energy1.00 mJFrequency20.0 kHz200.0 kHzPulse Width100.0 nsFluence @ 2 mm0.03 J/cm²Fluence @ 5 mm0.01 J/cm²Beam Quality M²1.60 Published datasheetCalculated from physicsP-Laser range
Each row is scaled to the P-Laser lineup max for that property (not a shared multi-unit axis). Validate against machine calibration before production use.

Pulse energy on P-Laser

QFC-300 highlighted among P-Laser systems with datasheet max pulse energy (mJ). Color = architecture.

Parity basis: datasheet max pulse energy (mJ) only · pulsed · ~1064 nm · shared contaminant thresholds · modeled spot (not a certified cross-OEM test).0.00316394125P-Laser QF-2000: 100 mJ · Q-HEP-Laser QF-2000100 mJ · Q-HEP-Laser QF-1000: 100 mJ · Q-HEP-Laser QF-1000100 mJ · Q-HEP-Laser QF-500: 50 mJ · Q-HEP-Laser QF-50050 mJ · Q-HEP-Laser ECO-C 500: 1.5 mJ · Q-stdP-Laser ECO-C 5001.5 mJ · Q-stdP-Laser QFC-300: 1.0 mJ · Q-std (this machine)P-Laser QFC-3001.0 mJ · Q-stdP-Laser ECO-C 200: 1.0 mJ · Q-stdP-Laser ECO-C 2001.0 mJ · Q-stdP-Laser QFC-200: 1.0 mJ · Q-stdP-Laser QFC-2001.0 mJ · Q-stdP-Laser QFC-100: 1.0 mJ · Q-stdP-Laser QFC-1001.0 mJ · Q-stdP-Laser QFC-50: 1.0 mJ · Q-stdP-Laser QFC-501.0 mJ · Q-std
  • Q-HE
  • Q-std
  • MOPA
  • CW
  • This machine
Parity basis: datasheet max pulse energy (mJ) only · pulsed · ~1064 nm · shared contaminant thresholds · modeled spot (not a certified cross-OEM test).

Fleet Power vs. Pulse Energy

Where the P-Laser QFC-300 sits among 52 laser-cleaning machines with published power and pulse energy. Log-scale axes; shape = architecture; orange highlight = this machine.

Scatter plot of machine max power versus pulse energy104050801001602503206401.0k1.3k1.3k2.6k124581016253264100125128256Max Power (W)Pulse Energy (mJ)Netalux Jango®: 200 W, 100 mJcleanLASER CL1000iF: 1000 W, 10 mJPULSAR Laser SHARK P CL 100M: 100 W, 1.5 mJPULSAR Laser SHARK P CL 200M: 200 W, 1.5 mJPULSAR Laser SHARK P CL 300M: 300 W, 1.5 mJPULSAR Laser SHARK P CL 500A: 500 W, 1.5 mJPULSAR Laser SHARK P CL 1000A: 1000 W, 1.5 mJLaserax LXQ-UHP Series (500W–3kW): 1750 W, 100 mJ4JET JETLASER M200: 200 W, 10 mJ4JET JETLASER M500: 500 W, 100 mJ4JET JETLASER M1000: 1000 W, 100 mJSenFeng SF500HC: 500 W, 50 mJSenFeng SF1000HC: 1000 W, 50 mJHan's Laser HC-PD: 125 W, 1.5 mJP-Laser QF-500: 500 W, 50 mJP-Laser QF-1000: 1000 W, 100 mJP-Laser QF-2000: 2000 W, 100 mJPowerlase Vulcan 500c: 500 W, 40 mJPowerlase FL-C100C: 100 W, 5 mJJNCT Laser 100W Air Cooling Laser Cleaning Machine: 100 W, 1 mJJNCT Laser 200W Air Cooling Laser Cleaning Machine: 200 W, 1 mJWuhan Sintec STPL-V-i500C: 500 W, 60 mJWuhan Sintec STPL-V-i1600: 1600 W, 250 mJHan's Laser HC-PD 50W: 50 W, 1.1 mJHan's Laser HC-PD 100W: 100 W, 1.5 mJHan's Laser HC-PD 200W: 200 W, 1.5 mJNetalux Needle 100: 100 W, 1 mJNetalux Needle 150: 150 W, 1 mJNetalux Needle 200: 200 W, 2 mJNetalux Needle 300: 300 W, 2 mJcleanLASER CL 500: 500 W, 25 mJP-Laser QFC-50: 50 W, 1 mJP-Laser QFC-100: 100 W, 1 mJP-Laser QFC-200: 200 W, 1 mJP-Laser QFC-300: 300 W, 1 mJ (this machine)Laserax LXQ-UHP 500W: 500 W, 100 mJLaserax LXQ-UHP 1000W: 1000 W, 100 mJLaserax LXQ-UHP 2000W: 2000 W, 150 mJLaserax LXQ-UHP 3000W: 3000 W, 150 mJFortune Laser FL-C200: 200 W, 2 mJFortune Laser FL-C300: 300 W, 2 mJP-Laser ECO-C 200: 200 W, 1 mJP-Laser ECO-C 500: 500 W, 1.5 mJNetalux Kamino 300: 300 W, 50 mJNarran ROD 300 Air: 300 W, 15 mJNarran ROD 500: 500 W, 50 mJNarran ROD 1000: 1000 W, 50 mJNarran ROD 2000: 2000 W, 100 mJNarran ROD 100 Air: 100 W, 1.54 mJNarran ROD 500 Bright+: 500 W, 100 mJNarran ROD 1000 Bright+: 1000 W, 100 mJNarran ROD 2000 Bright+: 2000 W, 100 mJ
Fleet power vs. pulse energy data
MachineMax Power (W)Pulse Energy (mJ)
Netalux Jango®200100
cleanLASER CL1000iF100010
PULSAR Laser SHARK P CL 100M1001.5
PULSAR Laser SHARK P CL 200M2001.5
PULSAR Laser SHARK P CL 300M3001.5
PULSAR Laser SHARK P CL 500A5001.5
PULSAR Laser SHARK P CL 1000A10001.5
Laserax LXQ-UHP Series (500W–3kW)1750100
4JET JETLASER M20020010
4JET JETLASER M500500100
4JET JETLASER M10001000100
SenFeng SF500HC50050
SenFeng SF1000HC100050
Han's Laser HC-PD1251.5
P-Laser QF-50050050
P-Laser QF-10001000100
P-Laser QF-20002000100
Powerlase Vulcan 500c50040
Powerlase FL-C100C1005
JNCT Laser 100W Air Cooling Laser Cleaning Machine1001
JNCT Laser 200W Air Cooling Laser Cleaning Machine2001
Wuhan Sintec STPL-V-i500C50060
Wuhan Sintec STPL-V-i16001600250
Han's Laser HC-PD 50W501.1
Han's Laser HC-PD 100W1001.5
Han's Laser HC-PD 200W2001.5
Netalux Needle 1001001
Netalux Needle 1501501
Netalux Needle 2002002
Netalux Needle 3003002
cleanLASER CL 50050025
P-Laser QFC-50501
P-Laser QFC-1001001
P-Laser QFC-2002001
P-Laser QFC-300 (current)3001
Laserax LXQ-UHP 500W500100
Laserax LXQ-UHP 1000W1000100
Laserax LXQ-UHP 2000W2000150
Laserax LXQ-UHP 3000W3000150
Fortune Laser FL-C2002002
Fortune Laser FL-C3003002
P-Laser ECO-C 2002001
P-Laser ECO-C 5005001.5
Netalux Kamino 30030050
Narran ROD 300 Air30015
Narran ROD 50050050
Narran ROD 1000100050
Narran ROD 20002000100
Narran ROD 100 Air1001.54
Narran ROD 500 Bright+500100
Narran ROD 1000 Bright+1000100
Narran ROD 2000 Bright+2000100
  • MOPA
  • Q-HE
  • Q-std
  • This machine
← P-Laser systems

Specifications sourced from manufacturer datasheets. Values are reference data — validate against your machine's actual calibration before production use.

P-Laser QFC-300 questions

  • How is the QFC-300 different from the P-Laser QF-300?

    Both carry 300 W[1], but the QFC-300 is the compact air-cooled unit while the QF-300 is a water-cooled high pulse power model. Pick the QFC-300 when moving the unit matters more than the heaviest coatings.

  • What pulse settings does the QFC-300 offer?

    Pulse width is set at 100 ns, and repetition rate adjusts across 20-200 kHz. Because the width never moves, the finish is tuned through rate, average power and how fast the beam travels.

  • What peak power does the QFC-300 reach?

    A 1 mJ pulse delivered in 100 ns gives about 10 kW of peak power. That makes a shorter, sharper hit than longer-pulse heads carrying the same pulse energy.

  • Which jobs suit the QFC-300 over the smaller QFC models?

    Choose it over the QFC-50, QFC-100 and QFC-200 when parts are larger or the run is longer, since the extra average power covers more area per hour. For molds and fine detail, pulsed heads like this one are the usual recommendation (Dynalaser fiber guide).

Sources(2 references)
  1. p-laser-qfc-300-specs p-laser.com (opens in new tab) — QFC-300: 300 W, 20-200 kHz, 100 ns, 1 mJ, air cooled
  2. dynalaser-pulsed-precision dynalaserstech.com (opens in new tab) — Pulsed sources are preferred for precision and mold work