P-Laser QF-2000 Laser Cleaning Parameters

P-Laser, "QF-2000: Everything you need to know", P-Laser News, 2024 p-laser.com (opens in new tab)

The QF-2000 is the 2000 W head in P-Laser's QF line, above the QF-300, QF-500 and QF-1000 and one step below the QF-3000. It exists for coatings too thick for lighter heads to break in reasonable time: each 100 ns pulse carries enough energy to crack heavy paint and scale away from the steel instead of slowly wearing it down. That earns it work on in-situ power plant cleaning, paint and coating removal and rust removal on large steel structures. Choose it when high pulse energy at a low repetition rate matters more than fine detail on thin films.

I'm from P-Laser and want to update this data

Published values come from public manufacturer datasheets and product pages. If you represent P-Laser and see an error, outdated figure, or missing model, send a short correction with a public source URL and we will review it.

  • Company name and your role
  • Machine model and the field to change
  • Correct value and units
  • Link to the official product page or datasheet

Email info@z-beam.com · Contact form

Published Specifications

BrandP-Laser
ModelQF-2000
OriginBelgium
Laser typeNanosecond pulsed fiber
Wavelength1064 nm
Average power2000 W
Max pulse energy100 mJ
Pulse width100 ns
Pulse frequency5–30 kHz
CoolingWater
Fiber length16 m
Beam quality (M²)< 2
CertificationsCE
Sources(1 reference)
  1. https://p-laser.com/news/qf-2000-everything-you-need-to-know p-laser.com (opens in new tab)

Parameter ranges

P-Laser QF-2000 positioned against other P-Laser machines. Orange/blue = this model; slate band = P-Laser min–max for that property. Missing properties are omitted.

Parameter rangesAvg Power2,000 WPulse Energy100.0 mJFrequency5.00 kHz30.0 kHzPulse Width100.0 nsFiber Length16.0 mBeam Quality M²2.00 Published datasheetP-Laser range
Each row is scaled to the P-Laser lineup max for that property (not a shared multi-unit axis). Validate against machine calibration before production use.

Pulse energy on P-Laser

QF-2000 highlighted among P-Laser systems with datasheet max pulse energy (mJ). Color = architecture.

Parity basis: datasheet max pulse energy (mJ) only · pulsed · ~1064 nm · shared contaminant thresholds · modeled spot (not a certified cross-OEM test).0.00316394125P-Laser QF-2000: 100 mJ · Q-HE (this machine)P-Laser QF-2000100 mJ · Q-HEP-Laser QF-1000: 100 mJ · Q-HEP-Laser QF-1000100 mJ · Q-HEP-Laser QF-500: 50 mJ · Q-HEP-Laser QF-50050 mJ · Q-HEP-Laser ECO-C 500: 1.5 mJ · Q-stdP-Laser ECO-C 5001.5 mJ · Q-stdP-Laser QFC-300: 1.0 mJ · Q-stdP-Laser QFC-3001.0 mJ · Q-stdP-Laser ECO-C 200: 1.0 mJ · Q-stdP-Laser ECO-C 2001.0 mJ · Q-stdP-Laser QFC-200: 1.0 mJ · Q-stdP-Laser QFC-2001.0 mJ · Q-stdP-Laser QFC-100: 1.0 mJ · Q-stdP-Laser QFC-1001.0 mJ · Q-stdP-Laser QFC-50: 1.0 mJ · Q-stdP-Laser QFC-501.0 mJ · Q-std
  • Q-HE
  • Q-std
  • MOPA
  • CW
  • This machine
Parity basis: datasheet max pulse energy (mJ) only · pulsed · ~1064 nm · shared contaminant thresholds · modeled spot (not a certified cross-OEM test).

Fleet Power vs. Pulse Energy

Where the P-Laser QF-2000 sits among 52 laser-cleaning machines with published power and pulse energy. Log-scale axes; shape = architecture; orange highlight = this machine.

Scatter plot of machine max power versus pulse energy104050801001602503206401.0k1.3k1.3k2.6k124581016253264100125128256Max Power (W)Pulse Energy (mJ)Netalux Jango®: 200 W, 100 mJcleanLASER CL1000iF: 1000 W, 10 mJPULSAR Laser SHARK P CL 100M: 100 W, 1.5 mJPULSAR Laser SHARK P CL 200M: 200 W, 1.5 mJPULSAR Laser SHARK P CL 300M: 300 W, 1.5 mJPULSAR Laser SHARK P CL 500A: 500 W, 1.5 mJPULSAR Laser SHARK P CL 1000A: 1000 W, 1.5 mJLaserax LXQ-UHP Series (500W–3kW): 1750 W, 100 mJ4JET JETLASER M200: 200 W, 10 mJ4JET JETLASER M500: 500 W, 100 mJ4JET JETLASER M1000: 1000 W, 100 mJSenFeng SF500HC: 500 W, 50 mJSenFeng SF1000HC: 1000 W, 50 mJHan's Laser HC-PD: 125 W, 1.5 mJP-Laser QF-500: 500 W, 50 mJP-Laser QF-1000: 1000 W, 100 mJP-Laser QF-2000: 2000 W, 100 mJ (this machine)Powerlase Vulcan 500c: 500 W, 40 mJPowerlase FL-C100C: 100 W, 5 mJJNCT Laser 100W Air Cooling Laser Cleaning Machine: 100 W, 1 mJJNCT Laser 200W Air Cooling Laser Cleaning Machine: 200 W, 1 mJWuhan Sintec STPL-V-i500C: 500 W, 60 mJWuhan Sintec STPL-V-i1600: 1600 W, 250 mJHan's Laser HC-PD 50W: 50 W, 1.1 mJHan's Laser HC-PD 100W: 100 W, 1.5 mJHan's Laser HC-PD 200W: 200 W, 1.5 mJNetalux Needle 100: 100 W, 1 mJNetalux Needle 150: 150 W, 1 mJNetalux Needle 200: 200 W, 2 mJNetalux Needle 300: 300 W, 2 mJcleanLASER CL 500: 500 W, 25 mJP-Laser QFC-50: 50 W, 1 mJP-Laser QFC-100: 100 W, 1 mJP-Laser QFC-200: 200 W, 1 mJP-Laser QFC-300: 300 W, 1 mJLaserax LXQ-UHP 500W: 500 W, 100 mJLaserax LXQ-UHP 1000W: 1000 W, 100 mJLaserax LXQ-UHP 2000W: 2000 W, 150 mJLaserax LXQ-UHP 3000W: 3000 W, 150 mJFortune Laser FL-C200: 200 W, 2 mJFortune Laser FL-C300: 300 W, 2 mJP-Laser ECO-C 200: 200 W, 1 mJP-Laser ECO-C 500: 500 W, 1.5 mJNetalux Kamino 300: 300 W, 50 mJNarran ROD 300 Air: 300 W, 15 mJNarran ROD 500: 500 W, 50 mJNarran ROD 1000: 1000 W, 50 mJNarran ROD 2000: 2000 W, 100 mJNarran ROD 100 Air: 100 W, 1.54 mJNarran ROD 500 Bright+: 500 W, 100 mJNarran ROD 1000 Bright+: 1000 W, 100 mJNarran ROD 2000 Bright+: 2000 W, 100 mJ
Fleet power vs. pulse energy data
MachineMax Power (W)Pulse Energy (mJ)
Netalux Jango®200100
cleanLASER CL1000iF100010
PULSAR Laser SHARK P CL 100M1001.5
PULSAR Laser SHARK P CL 200M2001.5
PULSAR Laser SHARK P CL 300M3001.5
PULSAR Laser SHARK P CL 500A5001.5
PULSAR Laser SHARK P CL 1000A10001.5
Laserax LXQ-UHP Series (500W–3kW)1750100
4JET JETLASER M20020010
4JET JETLASER M500500100
4JET JETLASER M10001000100
SenFeng SF500HC50050
SenFeng SF1000HC100050
Han's Laser HC-PD1251.5
P-Laser QF-50050050
P-Laser QF-10001000100
P-Laser QF-2000 (current)2000100
Powerlase Vulcan 500c50040
Powerlase FL-C100C1005
JNCT Laser 100W Air Cooling Laser Cleaning Machine1001
JNCT Laser 200W Air Cooling Laser Cleaning Machine2001
Wuhan Sintec STPL-V-i500C50060
Wuhan Sintec STPL-V-i16001600250
Han's Laser HC-PD 50W501.1
Han's Laser HC-PD 100W1001.5
Han's Laser HC-PD 200W2001.5
Netalux Needle 1001001
Netalux Needle 1501501
Netalux Needle 2002002
Netalux Needle 3003002
cleanLASER CL 50050025
P-Laser QFC-50501
P-Laser QFC-1001001
P-Laser QFC-2002001
P-Laser QFC-3003001
Laserax LXQ-UHP 500W500100
Laserax LXQ-UHP 1000W1000100
Laserax LXQ-UHP 2000W2000150
Laserax LXQ-UHP 3000W3000150
Fortune Laser FL-C2002002
Fortune Laser FL-C3003002
P-Laser ECO-C 2002001
P-Laser ECO-C 5005001.5
Netalux Kamino 30030050
Narran ROD 300 Air30015
Narran ROD 50050050
Narran ROD 1000100050
Narran ROD 20002000100
Narran ROD 100 Air1001.54
Narran ROD 500 Bright+500100
Narran ROD 1000 Bright+1000100
Narran ROD 2000 Bright+2000100
  • MOPA
  • Q-HE
  • Q-std
  • This machine
← P-Laser systems

Specifications sourced from manufacturer datasheets. Values are reference data — validate against your machine's actual calibration before production use.

P-Laser QF-2000 questions

  • Can the P-Laser QF-2000 stand in for a 2000 W rod laser?

    The QF-2000 sits in that 2000 W[1] class, but it is a nanosecond pulsed fiber source from P-Laser, not a ROD-series unit from another maker. It delivers up to 100 mJ per pulse at 100 ns, which works out to about 1 MW of peak power.

  • What is the QF-2000 designed to clean?

    P-Laser built it for fast decontamination of large areas in nuclear, shipbuilding and heavy industrial work. High pulse energy at a low repetition rate is what cracks and detaches thick coatings that lower-energy heads only thin.

  • At what frequency does the QF-2000 hold its full 100 mJ pulse?

    The full 100 mJ is available up to about 20 kHz at 2000 W[1]. At the 30 kHz top of its 5-30 kHz band each pulse drops to roughly 67 mJ, so thick layers favor the low end of the range.

  • Where does the QF-2000 fit in the P-Laser line?

    It is the highest-power trolley-series system, above the QF-500 and QF-1000 and below the 3000 W QF-3000. Smaller air-cooled QFC heads from 50 W to 300 W cover detail work the QF-2000 is too large for.

  • How far can the QF-2000 reach from its cabinet?

    The standard fiber is 16 m, and P-Laser offers cable lengths up to 100 m, so the water-cooled cabinet can stay put while the head travels across a hull or a plant floor.

  • What should be checked on the QF-2000 before installation?

    Plan for water cooling and confirm the CE marking on the unit's paperwork. Beam quality is listed at M² 2.0, and the class printed on the label sets the eyewear and zone controls.

Sources(1 reference)
  1. p-laser-qf-2000-overview p-laser.com (opens in new tab) — QF-2000: 2000 W, 5-30 kHz, 100 ns, 100 mJ max pulse energy