Skip to main content

Netalux Needle 150 Laser Cleaning Parameters

Discover mobile laser cleaning machine Needle® netalux.com (opens in new tab)

Adding 50 W over the Needle 100 while keeping the same fixed 150 ns pulse, the Needle 150 covers more surface per minute without changing how the beam treats the substrate. That consistency carries into delicate restoration work, where every pass has to behave like the last.

Netalux Needle 150 laser cleaning system
I'm from Netalux and want to update this data

Published values come from public manufacturer datasheets and product pages. If you represent Netalux and see an error, outdated figure, or missing model, send a short correction with a public source URL and we will review it.

  • Company name and your role
  • Machine model and the field to change
  • Correct value and units
  • Link to the official product page or datasheet

Email info@z-beam.com · Contact form

Derived Parameters

Peak power6.67 kW
Fluence at 2 mm spot0.0318 J/cm²
Fluence at 5 mm spot0.00509 J/cm²
Overlap (cleaning)60–80%

Field spot diameter varies by scan head — 2 mm and 5 mm are representative values for handheld cleaning heads.

Derived from published specifications.

Published Specifications

BrandNetalux
ModelNeedle 150
OriginBelgium
Laser typeQ-switched nanosecond pulsed fiber
Wavelength1064 nm
Average power150 W
Max pulse energy1 mJ
Pulse width150 ns
Pulse frequency10–500 kHz
CoolingAir
Weight19.3 kg
Beam quality (M²)< 1.6
Sources(1 reference)
  1. https://netalux.com/product/needle/ netalux.com (opens in new tab)

Parameter ranges

Netalux Needle 150 positioned against other Netalux machines. Orange/blue = this model; slate band = Netalux min–max for that property. Missing properties are omitted.

Parameter rangesAvg Power150.0 WPulse Energy1.00 mJFrequency10.0 kHz500.0 kHzPulse Width150.0 nsPeak Power6.67 kWFluence @ 2 mm0.03 J/cm²Fluence @ 5 mm0.01 J/cm²Weight19.3 kgBeam Quality M²1.60 Published datasheetCalculated from physicsNetalux range
Each row is scaled to the Netalux lineup max for that property (not a shared multi-unit axis). Validate against machine calibration before production use.

Pulse energy on Netalux

Needle 150 highlighted among Netalux systems with datasheet max pulse energy (mJ). Color = architecture.

Parity basis: datasheet max pulse energy (mJ) only · pulsed · ~1064 nm · shared contaminant thresholds · modeled spot (not a certified cross-OEM test).0.00316394125Netalux Jango®: 100 mJ · Q-HENetalux Jango®100 mJ · Q-HENetalux Kamino 300: 50 mJ · Q-HENetalux Kamino 30050 mJ · Q-HENetalux Needle 150: 1.0 mJ · Q-std (this machine)Netalux Needle 1501.0 mJ · Q-stdNetalux Needle 100: 1.0 mJ · Q-stdNetalux Needle 1001.0 mJ · Q-stdNetalux Needle 300: 2.0 mJ · MOPANetalux Needle 3002.0 mJ · MOPANetalux Needle 200: 2.0 mJ · MOPANetalux Needle 2002.0 mJ · MOPA
  • Q-HE
  • Q-std
  • MOPA
  • CW
  • This machine
Parity basis: datasheet max pulse energy (mJ) only · pulsed · ~1064 nm · shared contaminant thresholds · modeled spot (not a certified cross-OEM test).

Fleet Power vs. Pulse Energy

Where the Netalux Needle 150 sits among 52 laser-cleaning machines with published power and pulse energy. Log-scale axes; shape = architecture; orange highlight = this machine.

Scatter plot of machine max power versus pulse energy104050801001602503206401.0k1.3k1.3k2.6k124581016253264100125128256Max Power (W)Pulse Energy (mJ)Netalux Jango®: 200 W, 100 mJcleanLASER CL1000iF: 1000 W, 10 mJPULSAR Laser SHARK P CL 100M: 100 W, 1.5 mJPULSAR Laser SHARK P CL 200M: 200 W, 1.5 mJPULSAR Laser SHARK P CL 300M: 300 W, 1.5 mJPULSAR Laser SHARK P CL 500A: 500 W, 1.5 mJPULSAR Laser SHARK P CL 1000A: 1000 W, 1.5 mJLaserax LXQ-UHP Series (500W–3kW): 1750 W, 100 mJ4JET JETLASER M200: 200 W, 10 mJ4JET JETLASER M500: 500 W, 100 mJ4JET JETLASER M1000: 1000 W, 100 mJSenFeng SF500HC: 500 W, 50 mJSenFeng SF1000HC: 1000 W, 50 mJHan's Laser HC-PD: 125 W, 1.5 mJP-Laser QF-500: 500 W, 50 mJP-Laser QF-1000: 1000 W, 100 mJP-Laser QF-2000: 2000 W, 100 mJPowerlase Vulcan 500c: 500 W, 40 mJPowerlase FL-C100C: 100 W, 5 mJJNCT Laser 100W Air Cooling Laser Cleaning Machine: 100 W, 1 mJJNCT Laser 200W Air Cooling Laser Cleaning Machine: 200 W, 1 mJWuhan Sintec STPL-V-i500C: 500 W, 60 mJWuhan Sintec STPL-V-i1600: 1600 W, 250 mJHan's Laser HC-PD 50W: 50 W, 1.1 mJHan's Laser HC-PD 100W: 100 W, 1.5 mJHan's Laser HC-PD 200W: 200 W, 1.5 mJNetalux Needle 100: 100 W, 1 mJNetalux Needle 150: 150 W, 1 mJ (this machine)Netalux Needle 200: 200 W, 2 mJNetalux Needle 300: 300 W, 2 mJcleanLASER CL 500: 500 W, 25 mJP-Laser QFC-50: 50 W, 1 mJP-Laser QFC-100: 100 W, 1 mJP-Laser QFC-200: 200 W, 1 mJP-Laser QFC-300: 300 W, 1 mJLaserax LXQ-UHP 500W: 500 W, 100 mJLaserax LXQ-UHP 1000W: 1000 W, 100 mJLaserax LXQ-UHP 2000W: 2000 W, 150 mJLaserax LXQ-UHP 3000W: 3000 W, 150 mJFortune Laser FL-C200: 200 W, 2 mJFortune Laser FL-C300: 300 W, 2 mJP-Laser ECO-C 200: 200 W, 1 mJP-Laser ECO-C 500: 500 W, 1.5 mJNetalux Kamino 300: 300 W, 50 mJNarran ROD 300 Air: 300 W, 15 mJNarran ROD 500: 500 W, 50 mJNarran ROD 1000: 1000 W, 50 mJNarran ROD 2000: 2000 W, 100 mJNarran ROD 100 Air: 100 W, 1.54 mJNarran ROD 500 Bright+: 500 W, 100 mJNarran ROD 1000 Bright+: 1000 W, 100 mJNarran ROD 2000 Bright+: 2000 W, 100 mJ
Fleet power vs. pulse energy data
MachineMax Power (W)Pulse Energy (mJ)
Netalux Jango®200100
cleanLASER CL1000iF100010
PULSAR Laser SHARK P CL 100M1001.5
PULSAR Laser SHARK P CL 200M2001.5
PULSAR Laser SHARK P CL 300M3001.5
PULSAR Laser SHARK P CL 500A5001.5
PULSAR Laser SHARK P CL 1000A10001.5
Laserax LXQ-UHP Series (500W–3kW)1750100
4JET JETLASER M20020010
4JET JETLASER M500500100
4JET JETLASER M10001000100
SenFeng SF500HC50050
SenFeng SF1000HC100050
Han's Laser HC-PD1251.5
P-Laser QF-50050050
P-Laser QF-10001000100
P-Laser QF-20002000100
Powerlase Vulcan 500c50040
Powerlase FL-C100C1005
JNCT Laser 100W Air Cooling Laser Cleaning Machine1001
JNCT Laser 200W Air Cooling Laser Cleaning Machine2001
Wuhan Sintec STPL-V-i500C50060
Wuhan Sintec STPL-V-i16001600250
Han's Laser HC-PD 50W501.1
Han's Laser HC-PD 100W1001.5
Han's Laser HC-PD 200W2001.5
Netalux Needle 1001001
Netalux Needle 150 (current)1501
Netalux Needle 2002002
Netalux Needle 3003002
cleanLASER CL 50050025
P-Laser QFC-50501
P-Laser QFC-1001001
P-Laser QFC-2002001
P-Laser QFC-3003001
Laserax LXQ-UHP 500W500100
Laserax LXQ-UHP 1000W1000100
Laserax LXQ-UHP 2000W2000150
Laserax LXQ-UHP 3000W3000150
Fortune Laser FL-C2002002
Fortune Laser FL-C3003002
P-Laser ECO-C 2002001
P-Laser ECO-C 5005001.5
Netalux Kamino 30030050
Narran ROD 300 Air30015
Narran ROD 50050050
Narran ROD 1000100050
Narran ROD 20002000100
Narran ROD 100 Air1001.54
Narran ROD 500 Bright+500100
Narran ROD 1000 Bright+1000100
Narran ROD 2000 Bright+2000100
  • MOPA
  • Q-HE
  • Q-std
  • This machine
← Netalux systems

Specifications sourced from manufacturer datasheets. Values are reference data — validate against your machine's actual calibration before production use.

Netalux Needle 150 questions

  • Which Netalux laser is the Needle 150?

    The Needle 150 is a 150 W[1] Q-switched nanosecond fiber head at 1064 nm, one step above the Needle 100 and the strongest Needle that keeps a fixed pulse width. Each 1 mJ pulse spread on a 2 mm spot lands near 0.032 J/cm².

  • Why choose the Needle 150 over the Needle 100 as a Netalux laser cleaner?

    The Needle 150 and Needle 100 share the same 1 mJ pulse and 150 ns width, so the extra 50 W adds coverage speed, not a harder hit per pulse. Pick the Needle 150 w[1]hen the surface responds well to the Needle 100 but the parts are larger.

  • How high can the Needle 150 run before pulse energy drops?

    Full 1 mJ pulses hold up to about 150 kHz at 150 W[1]. Pushing toward the 500 kHz top of its 10-500 kHz band thins each pulse to roughly 0.3 mJ, useful for light films that mark easily.

  • What peak power does the Needle 150 reach?

    A 1 mJ pulse squeezed into 150 ns gives about 6.7 kW of peak power. That figure stays the same as on the Needle 100, since only average power differs between the two.

  • Is the Needle 150 easy to move between work areas?

    It runs on air cooling and weighs about 19.3 kg, so it needs only a power outlet at the next station. Water cooling enters the Needle range only at the Needle 500.

  • Which laser class applies to the Needle 150?

    The label and compliance file on the unit settle the class. Open handheld fiber cleaners of this type are usually treated as Class 4 (Laser Photonics guide), so plan rated eyewear for 1064 nm, a closed work zone and trained operators.

Sources(2 references)
  1. netalux-needle-150-specs netalux.com (opens in new tab) — Needle 150: 150 W, 150 ns, 10-500 kHz, 1 mJ, air cooled
  2. laserphotonics-class4-handheld laserphotonics.com (opens in new tab) — Open handheld fiber cleaners are treated as Class 4 products