On-Site Demo
- CoversCoverage SF Bay Area
- Test your material
Discover mobile laser cleaning machine Needle® netalux.com (opens in new tab)
The Needle 200 is where the line moves from a fixed pulse to independently adjustable pulse width and frequency, with 2 mJ available at 200 W. Shaping the pulse around the contaminant lets operators clear overhead weld-seam oxide without overheating thin sections nearby.

Published values come from public manufacturer datasheets and product pages. If you represent Netalux and see an error, outdated figure, or missing model, send a short correction with a public source URL and we will review it.
| Fluence at 2 mm spot | 0.0637 J/cm² |
| Fluence at 5 mm spot | 0.0102 J/cm² |
| Overlap (cleaning) | 60–80% |
Entity-fact-cited specifications for the Netalux Needle 200 sourced from the canonical machines entity registry. Each row is anchored to a citation.
| Brand | Netalux |
| Model | Needle 200 |
| Origin | Belgium |
| Laser type | MOPA pulsed ytterbium fiber |
| Wavelength | 1064 nm |
| Average power | 200 W |
| Max pulse energy | 2 mJ |
| Pulse width | 20–500 ns (adjustable) |
| Pulse frequency | 2–4000 kHz |
| Cooling | Air |
| Weight | 43 kg |
| Beam quality (M²) | < 1.6 |
Netalux Needle 200 positioned against other Netalux machines. Orange/blue = this model; slate band = Netalux min–max for that property. Missing properties are omitted.
Needle 200 highlighted among Netalux systems with datasheet max pulse energy (mJ). Color = architecture.
Where the Netalux Needle 200 sits among 52 laser-cleaning machines with published power and pulse energy. Log-scale axes; shape = architecture; orange highlight = this machine.
| Machine | Max Power (W) | Pulse Energy (mJ) |
|---|---|---|
| Netalux Jango® | 200 | 100 |
| cleanLASER CL1000iF | 1000 | 10 |
| PULSAR Laser SHARK P CL 100M | 100 | 1.5 |
| PULSAR Laser SHARK P CL 200M | 200 | 1.5 |
| PULSAR Laser SHARK P CL 300M | 300 | 1.5 |
| PULSAR Laser SHARK P CL 500A | 500 | 1.5 |
| PULSAR Laser SHARK P CL 1000A | 1000 | 1.5 |
| Laserax LXQ-UHP Series (500W–3kW) | 1750 | 100 |
| 4JET JETLASER M200 | 200 | 10 |
| 4JET JETLASER M500 | 500 | 100 |
| 4JET JETLASER M1000 | 1000 | 100 |
| SenFeng SF500HC | 500 | 50 |
| SenFeng SF1000HC | 1000 | 50 |
| Han's Laser HC-PD | 125 | 1.5 |
| P-Laser QF-500 | 500 | 50 |
| P-Laser QF-1000 | 1000 | 100 |
| P-Laser QF-2000 | 2000 | 100 |
| Powerlase Vulcan 500c | 500 | 40 |
| Powerlase FL-C100C | 100 | 5 |
| JNCT Laser 100W Air Cooling Laser Cleaning Machine | 100 | 1 |
| JNCT Laser 200W Air Cooling Laser Cleaning Machine | 200 | 1 |
| Wuhan Sintec STPL-V-i500C | 500 | 60 |
| Wuhan Sintec STPL-V-i1600 | 1600 | 250 |
| Han's Laser HC-PD 50W | 50 | 1.1 |
| Han's Laser HC-PD 100W | 100 | 1.5 |
| Han's Laser HC-PD 200W | 200 | 1.5 |
| Netalux Needle 100 | 100 | 1 |
| Netalux Needle 150 | 150 | 1 |
| Netalux Needle 200 (current) | 200 | 2 |
| Netalux Needle 300 | 300 | 2 |
| cleanLASER CL 500 | 500 | 25 |
| P-Laser QFC-50 | 50 | 1 |
| P-Laser QFC-100 | 100 | 1 |
| P-Laser QFC-200 | 200 | 1 |
| P-Laser QFC-300 | 300 | 1 |
| Laserax LXQ-UHP 500W | 500 | 100 |
| Laserax LXQ-UHP 1000W | 1000 | 100 |
| Laserax LXQ-UHP 2000W | 2000 | 150 |
| Laserax LXQ-UHP 3000W | 3000 | 150 |
| Fortune Laser FL-C200 | 200 | 2 |
| Fortune Laser FL-C300 | 300 | 2 |
| P-Laser ECO-C 200 | 200 | 1 |
| P-Laser ECO-C 500 | 500 | 1.5 |
| Netalux Kamino 300 | 300 | 50 |
| Narran ROD 300 Air | 300 | 15 |
| Narran ROD 500 | 500 | 50 |
| Narran ROD 1000 | 1000 | 50 |
| Narran ROD 2000 | 2000 | 100 |
| Narran ROD 100 Air | 100 | 1.54 |
| Narran ROD 500 Bright+ | 500 | 100 |
| Narran ROD 1000 Bright+ | 1000 | 100 |
| Narran ROD 2000 Bright+ | 2000 | 100 |
The Needle 200 is where Netalux moves from fixed-pulse Q-switched heads to a MOPA fiber source, at 200 W[1] and 1064 nm. Pulse width now adjusts across 20-500 ns and repetition rate across 2-4000 kHz, each set on its own.
The Needle 200 suits a workload that swings between delicate and stubborn layers, since short pulses limit heat on sensitive parts and long pulses push harder on tougher films. Its 2 mJ maximum pulse on a 2 mm spot reaches about 0.064 J/cm², double the Needle 150.
At 200 W[1] the full 2 mJ is available up to about 100 kHz. Above that rate the energy per pulse falls as frequency climbs, which is the setting range for light cleaning at high coverage.
It stays air cooled, but at about 43 kg it is more than twice the weight of the Needle 100 and 150, so plan on rolling it rather than carrying it between stations.